Tips for picking a Reliable Extension Socket 2 Copper strands cables
Posted by Surya Tech on
We discovered, in the current UK market, some poor extensions use cables with mixture of aluminum and copper strands.
As aluminum has a much lower melting point, once a higher current passed through, excessive heat may be generated and melt the aluminum strands material.
After the aluminium strands melted, the cross-sectional area of the cable will decrease, and reduce its electrical rating. The remaining cable strands will heated up more seriously and easily caught fire.
A reliable BS extension socket with 3 meter cable, should use at least 1.25mm2 copper strand flexible cables. This cable allows the extension to take up to 13A loading.